Instructions
- Attempt five questions in all selecting at least two questions from each Section.
- Each question carries 20 marks.
- Use of calculator is allowed.
Questions
Section-A
- QQues1. a) What is the significance of load flow study? Also discuss the importance of acceleration factor. (10) b) Why Y-bus is used for load flow studies? Write its properties? (10) [20 marks]
- QQues2. a) Form y-bus for the 4-bus system as given in the table Line (bus to bus) | Impedance 1-2 | $0.15 + j0.6$ pu 1-3 | $0.1 + j0.4$ pu 1-4 | $0.15 + j0.6$ pu 2-3 | $0.05 + j0.2$ pu 3-4 | $0.05 + j0.2$ pu (10) b) Obtain the z-bus by building procedure (10) p-q (nodes) | impedance 0-1 | 0.25 0-2 | 0.20 1-2 | 0.08 2-3 | 0.06 [20 marks]
- QQues3. For the network shown in fig obtain the complex bus bar voltage at bus 2 at the end of the first iteration using gauss-siedel method. Line impedance are (20) Given Bus 1 is slack bus with $V_1 = 1.0\angle 0^\circ$, $P_2 + jQ_2 = -5.96 + j1.46$, $|V_3| = 1.02$ pu Assume $V_3 = 1.02\angle 0^\circ$ and $V_2 = 1.0\angle 0^\circ$ [20 marks]
- QQues4. Write the algorithm for load flow solution using Newton-Raphson method. Also draw its flow chart (20) [20 marks]
Section-B
- QQues5. How equal area criterion is used for the power system stability? Write its applications. (20) [20 marks]
- QQues6. a) Write the expression for the numerical solution of swing equation. (10) b) Distinguish between steady state stability, transient stability and dynamic stability. (10) [20 marks]
- QQues7. a) Write short note on optimum power flow? (10) b) Derive the expression for representation of transmission loss by $\beta$-coefficient. (10) [20 marks]
- QQues8. a) A power consist of two 200 MW units, whose input cost is given by (12) $F_1 = 0.004\,P_1^2 + 2.0\,P_1 + 80$ $F_2 = 0.006\,P_2^2 + 1.5\,P_2 + 100$ For the total load of 250 MW What should be the division of load between two units of most economic operation? b) What do you mean by unit commitment? (8) [20 marks]